Apex FiltaMate Pressure Limiting Valve 600kPa- FM600

Model: FM600

FM600 - 600 kPa Brass/Nickel Plated with Dual Check Valves 

Application:

  • High pressure systems to protect downstream components, e.g. Water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines.
  • Mobile homes and caravans where a connection is available to mains water.  

Standards:

  • Complies with NZ Building Code G12 (2001)
  • Complies with NZS 4608:1992
  • Australian Watermark Approval AS1357.2 Lic. 02596
  • Australian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1/2 only)  
  • FM & FM 1/2 are precision machined from high quality NZ brass. FM valve is nickel plated.
  • Integral dual check valves help prevent backflow (Not included all models - see specifications and product codes below).
  • Integral line strainer protects device and eliminates need for additional strainer to be fitted upstream. (Not included all models - see specifications and product codes below).
  • FiltaMate resists water hammer and limits water pressure to filters thus avoiding costly water damage.

Installation:

  • Installation must be carried out by a Qualified Person.
  • All pipe work must be flushed prior to installation.
  • Do NOT apply heat near valve during installation.
  • Must be fitted downstream of approved isolating valves.
  • Must be installed in the direction as indicated by the flow arrow.
  • Must be protected by a line strainer (See specifications and product codes for valves with integral line strainer).
  • Must be installed according to local regulations.
  • May be fitted in any orientation.
  • Warranty is limited to any fault found in a valve due to poor workmanship or materials that is returned to Apex Valves Ltd within 1 year from the date of manufacture.
  • If thermal expansion (due to heating, cooling) or back pressure can occur downstream, an expansion valve must be fitted to relieve the excessive pressure build up.

Servicing: 

The FiltaMate valve opens and closes automatically every time water is drawn through it. As it is a mechanical device we recommend that it is replaced every 5 years or sooner in high usage installations.

  • Inlet: 15mm, 1/2" BSP (female)
  • Outlet: 8mm 1/4" BSP (female)
  • Length: 97mm
  • Integral Line Strainer: Yes
  • Check Valve: Dual
  • Flow Rate: 14 L/min [4 USgpm] at 700 kPa [100psi] inlet pressure 
  • Pressure ratio: 10:1 (for every 10 kPa [1.5psi] increase in inlet pressure above 1000 kPa [150psi], the outlet pressure will increase by 1 kPa [0.145psi]).  
  • Outlet pressures: 350 and 600 kPa [50, 60 and 85psi] +/- 10% @ 1000 kPa [150psi] inlet pressure (Contact Apex Valves for additional pressures available).  
  • Maximum inlet pressure: 1600 kPa [230psi]  
  • Maximum Tempreture: 40˚C [105˚F]; 60˚C [140˚] for FM and FM 1/2 
  • Minimum Tempreture: 1°C
  • FMP supplied with fixing clip and screw.
  • FM DR (Dezincification Resistant) brass.
  • FMP Acetyl plastic.
  • FMBP DR brass inlet, acetyl plastic outlet  